  • The energy measuring module can process measured data at a refresh cycle of 10 ms and is ideal for energy saving and predictive maintenance at the manufacturing site.

  • RE81WH
    • RE81WH

Highly detailed energy measurements by simple setting and installation

  • Easy installation and setting
  • Highly detailed measuring
  • By directly installing the module on a vacant slot of the base unit, measurement functions can be added without changing the layout in the control panel
  • Setup is easily done with the engineering software GX Works3 without having to develop a program
  • Highly detailed energy measuring at a refresh cycle of 10 ms, which is ideal for manufacturing equipment for beverage and semiconductor industries

Highly detailed energy measurements by simple setting and installation

Visualize CO2 emissions and other data in coordination with e-F@ctory starter package

  • CO2 emissions management
  • Visualization
Visualize CO2 emissions and other data in coordination with e-F@ctory starter package
  • CO2 emissions, specific energy consumption, production volume, and electric energy can be easily checked with free sample projects of programmable controller and GOT (HMI)
  • CO2 emissions are displayed on the GOT (HMI) allowing real-time monitoring on the shop floor. This will help raise awareness of CO2 emission reduction in manufacturing
  • Electric energy and production volume data are saved for energy loss analysis per production line and equipment process

Energy measuring module specifications

Item RE81WH
Number of measurable circuits 1
Phase-wire systems Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire common
Current circuit (A AC) 5, 50, 100, 250, 400, 600*1
5*2
Voltage circuit
Single-phase 2-wire, three-phase 3-wire (V AC) 110, 220 common*3
Single-phase 3-wire (V AC) 110 (1-2 lines, 2-3 lines), 220 (1-3 lines)
Measurement specifications
Data refreshing cycle (ms) 10…10000*4
Measurement items Current, current demand, voltage, electric power, electric power demand, reactive power, apparent power, harmonic current, harmonic voltage, frequency, power factor, electric energy, reactive energy

*1.A value when a dedicated split-type current sensor is used. Each value indicates current sensor’s primary current value.

*2.A value when a dedicated 5 A current sensor is used. A 5 A current sensor is used with two-stage configuration in combination with a current transformer (CT). Primary current value can be set up to 6000 A.

*3.Up to 6600 V can be set in combination with a voltage transformer (VT).

*4.Can be set in increments of 10 ms.